Bendel stainless steel storage tank and heat exchanger fabricators.Bendel Tank & Heat Exchanger invites you to download our handy engineering calculator tools to use freely on your desktop!

It’s easy to do.  Just visit this link and follow the easy download instructions!

Our free desktop tools give you calculators that you can use to calculate Pressure, Capacity, Flow, Temperature, Volume and Finishes.  Every calculation that Bendel Storage Tank, Pressure Vessel & Heat Exchanger engineering calculator from the fabricator.you would need to make to design and configure a tank or vessel is contained within the calculators.

We also included handy conversion tools within the calculators for Surface Finish, Grit Size, Mass, Density, Length, Volume, Pressure/Vacuum, and Temperature.

We hope you enjoy using the Bendel Desktop Tools Widget and please give us a call at 1-866-596-5112 if you have any questions that we may help you with.  Thank you and have a great 2011!

 

Friday, November 26, 2010

Heat Exchanger Fabricator Has Flow Arrangement Options

We have been posting some “behind-the-scenes” and educational information about Heat Exchangers, how they work, what is the science behind them, etc.  And now we want to take a look at “flow arrangement” and how we classify flow arrangement when fabricating our Heat Exchangers.

Parallel flow shell & tube heat exchanger fabrication from Bendel Tank & Heat Exchanger in Charlotte, NC.Basically, there are two primary classifications of heat exchangers according to their flow arrangement. In parallel-flow heat exchangers (at left), the two fluids enter the exchanger at the same end, and travel in parallel to one another to the other side.

In counter-flow heat exchangers (at right) the fluids enter the exchanger from opposite endsCounter current shell & tube heat exchanger fabrication from Bendel Tank & Heat Exchanger in Charlotte, NC.. The counter current design is most efficient, in that it can transfer the most heat from the heat (transfer) medium.

For efficiency, heat exchangers are designed to maximize the surface area of the wall between the two fluids, while minimizing resistance to fluid flow through the exchanger. The exchanger’s performance can also be affected by the addition of fins or corrugations in one or both directions, which increase surface area and may channel fluid flow or induce turbulence.

Cross flow shell & tube heat exchanger fabrication at Bendel Tank & Heat Exchanger in Charlotte, NC.In a cross-flow heat exchanger (at left), the fluids travel roughly perpendicular to one another through the exchanger.

The driving temperature across the heat transfer surface varies with position, but an appropriate mean temperature can be defined. In most simple systems this is the “log mean temperature difference” (LMTD). Sometimes direct knowledge of the LMTD is not available and the NTU (Number of Transfer Units) method is used.

If you would like more information about our Bendel heat exchanger design and fabricating program, please call us at 866-596-5112 or contact  Vince Petrucci or Vivek Patel at Bendel.

 

Friday, October 29, 2010

U-tube Heat Exchanger Design and Fabrication from Bendel Corporation

There are several different types of shell and tube heat exchangers that Bendel designs and fabricates for clients of varying types for varying uses!  The U-tube heat exchanger is a multi-use heat exchanger that many of our clients use in their various manufacturing processes.

U-tube heat exchanger design and fabrication from Bendel Corporation in Charlotte, NC.A shell and tube heat exchanger is a class of heat exchanger designs. It is the most common type of heat exchanger in oil refineries and other large chemical processes, and is suited for higher-pressure applications. As its name implies, this type of heat exchanger consists of a shell (a large pressure vessel) with a bundle of tubes inside it. One fluid runs through the tubes, and another fluid flows over the tubes (through the shell) to transfer heat between the two fluids. The set of tubes is called a tube bundle, and may be composed by several types of tubes: plain, longitudinally finned, etc.

Two fluids, of different starting temperatures, flow through the heat exchanger. One flows through the tubes (the tube side) and the other flows outside the tubes but inside the shell (the shell side). Heat is transferred from one fluid to the other through the tube walls, either from tube side to shell side or vice verse. The fluids can be either liquids or gases on either the shell or the tube side. In order to transfer heat efficiently, a large heat transfer area should be used, leading to the use of many tubes. In this way, waste heat can be put to use. This is an efficient way to conserve energy.

Heat exchangers with only one phase (liquid or gas) on each side can be called one-phase or single-phase heat Heat Exchanger shell tube sheet fabrication from Bendel in Charlotte, NC.exchangers. Two-phase heat exchangers can be used to heat a liquid to boil it into a gas (vapor), sometimes called boilers, or cool a vapor to condense it into a liquid (called condensers), with the phase change usually occurring on the shell side. Boilers in steam engine locomotives are typically large, usually cylindrically-shaped shell-and-tube heat exchangers. In large power plants with steam-driven turbines, shell-and-tube surface condensers are used to condense the exhaust steam exiting the turbine into condensate water which is recycled back to be turned into steam in the steam generator.

There can be many variations on the shell and tube design. Typically, the ends of each tube are connected to plenums (sometimes called water boxes) through holes in tubesheets. The tubes may be straight or bent in the shape of a U, called U-tubes.

If you would like more information about our Bendel heat exchanger design and fabricating program, please call us at 866-596-5112 or contact  Vince Petrucci or Vivek Patel at Bendel.